23
SECTION 16: CLEANING THE CERAMICS
Remove the fascia if required, see Section 9.
Remove the ceramic components.
Gently clean in the open air using a dry paint brush.
Be careful not to create dust from the coals.
Where necessary replace damaged components with genuine spares.
Seal scrap ceramic components in plastic bags and dispose at proper refuse sites as directed.
Re-fit the fuel bed by referring to the relevant sections of these instructions
.
SECTION 17: TROUBLESHOOTING GUIDE
Fire sparks but pilot Flame does not light?
A pilot light but then goes out before main burner lights?
Fire does not spark at pilot
?
No gas to fire, check isolating valves are open.
Pipe work blockage, clean out.
Air not fully purged, re-purge supply or wait longer.
Spark earthing to metal work, reset gap correctly.
Blocked pilot, clean out internally.
Severe restriction in gas supply, clear obstruction.
Faulty thermocouple, replace pilot unit.
Hold control knob in for longer.
Run through lighting system on the remote control
several times allowing the valve to rest each time.
HT lead detached, refit.
Spark gap too large or small reset correctly.
Spark shorting to metalwork under tray, re-align HT
lead
Содержание Royal Solo Apex
Страница 38: ...38 SECTION 20 LIST OF SPARES Royal 600 Manual Controls C1 C 4 C2 C3 B1 ...
Страница 39: ...39 SECTION 20 LIST OF SPARES Royal 1000 Manual Controls A5 A6 A4 A7 C1 C 4 C2 C3 B1 ...
Страница 40: ...40 Royal 400 Remote Control A5 A6 A4 A7 C1 C 4 C2 C3 ...
Страница 41: ...41 Royal 600 Remote Control A2 A3 A4 A1 A2 A3 A1 A4 ...
Страница 42: ...42 Royal 1000 Remote Control 5E 2E 3E 4E 6E 13E 10E 12E 7E 11E A1 A2 A3 A4 ...
Страница 43: ...43 Royal 400 Ceramics Royal 600 Ceramics Royal 1000 Ceramics F1 F3 F5 ...