SECTION 5.1: PREFABRICATED FLUES
These appliances can be fitted to a prefabricated flue system, the 400 model will require a
flue box but the 600 and 1000 appliance can be fitted directly to the appliance via a flue
adaptor (sold separately)
All will require a false chimney breast in which to be housed and will need to be constructed
of a non-combustible material or any combustible material within 300mm must be clad with a
non-combustible board.
The correct clearances to combustible materials (i.e. false chimney breast etc) must be
adhered to.
The manufacturer of the prefabricated box’s instructions for fitting the prefabricated box must
be complied with at all times.
Please ensure the firebox does not obscure the flue box outlet.
It is important that the sealing requirements of the appliance are met at all times and that
the flue box is sealed to any back or infill panel.
Section 6: DEBRIS SPACE
In accordance with BS 5871 part 2, minimum debris collection volumes are required
behind the installed appliance.
CLAY/CEMENT LINES OR BLOCK FLUE WHICH IS NEW, UNUSED, OR PREVIOUSLY
ONLY USED WITH A GAS FIRE.
Appliance recessed depth + 20mm
UNLINED FLUE OR CHIMNEY WHICH HAS BEEN PREVIOUSLY USED FOR A SOLID
FUEL OR OIL BURNING APPLIANCE
Appliance recessed depth + 60mm
Содержание Royal Solo Apex
Страница 38: ...38 SECTION 20 LIST OF SPARES Royal 600 Manual Controls C1 C 4 C2 C3 B1 ...
Страница 39: ...39 SECTION 20 LIST OF SPARES Royal 1000 Manual Controls A5 A6 A4 A7 C1 C 4 C2 C3 B1 ...
Страница 40: ...40 Royal 400 Remote Control A5 A6 A4 A7 C1 C 4 C2 C3 ...
Страница 41: ...41 Royal 600 Remote Control A2 A3 A4 A1 A2 A3 A1 A4 ...
Страница 42: ...42 Royal 1000 Remote Control 5E 2E 3E 4E 6E 13E 10E 12E 7E 11E A1 A2 A3 A4 ...
Страница 43: ...43 Royal 400 Ceramics Royal 600 Ceramics Royal 1000 Ceramics F1 F3 F5 ...