9
2.3 - ELECTRICAL CONNECTION
Check that the data reported on the
technical-part number plate (Fig. n°18), in the
delivery documents, correspond in the right order;
contact the supplier for clarification if they do not.
At this point make sure that the system is
standard and that the cable and grounding
system perfectly operate.
2.3.1 - Slicer with single-phase motor
The slicer is equipped with a feeding cable with a cross section area of 3x1mm²; length
≅
1.5m and
a “SHUKO” plug. Connect the 230 V. - 50 Hz slicer, interposing a magnetothermic differential switch
of 10A,
Ι∆
= 0.03A.
2.3.2 - Slicer with 400 V. three-phase motor
The slicer is equipped with a feeding cable with a cross section area of 5x1mm², length
≅
1.5m and
a red 15A 3F + T CEI plug. Connect the slicer to the 400 V. - 50Hz three-phase supply mains,
interposing a magnetothermic differential switch of 10 A,
Ι∆
=0.03A.
2.3.3 - Blade rotation direction
Check the direction of the blade rotation with a
pulse of the “I” push-button (ON),
immediately followed by the “0” push-button OFF.
The direction of the blade rotation must be
counter-clockwise when looking at the slicer from
the bladeguard side (Fig. n°19). In the case that
the rotation direction is not exact, invert (Fig. n°
20) the position of two of the three phase wires
(black, gray or brown) in the plug.
Fig. n°18
LEGEND
(A)
= Product code and name
(B)
= Power supply
(C)
= Motor frequency
(D)
= Amperage
(E)
= Serial number
(F)
= Barcode
(G)
= Manifacturer
(H)
= International Protection
(I)
= Weight
(L)
= Power
(M)
= Origin
(A)
(B)
(C)
(D)
(E)
(H)
(I)
(L)
(F)
(G)
(M)
Fig. n°19
Fig. n°20
2.3.4 - Slicer with 230 V. three-phase motor
The slicer is equipped with a feeding cable with a section area of 5x1mm²; length
≅
1.5m and a blue
15A 3F + T CEI plug.
Connect the slicer 230 V. - 50 Hz three-phase supply mains, interposing a magnetothermic
differential switch of 10A,
∆
I= 0.03A.
Check that the direction of the blade rotation is counter-clockwise looking at the slicer from the side
of the bladeguard. If not proceed as in 2.3.3.