![Simex SRD-99 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/simex/srd-99/srd-99_user-manual_1275363068.webp)
User manual - DATA RECORDER SRD-99 and cooperating software
Register Write
Range
Register description
Register from E0h to E5h
Alarm parameters in “
Inputs settings
” submenu for channel 5;
registry description like for channel 1 (see registers C0h to C5h).
Register from E8h to EDh
Alarm parameters in “
Inputs settings
” submenu for channel 6;
registry description like for channel 1 (see registers C0h to C5h).
Register from F0h to F5h
Alarm parameters in “
Inputs settings
” submenu for channel 7;
registry description like for channel 1 (see registers C0h to C5h).
Register from F8h to FDh
Alarm parameters in “
Inputs settings
” submenu for channel 8;
registry description like for channel 1 (see registers C0h to C5h).
Configuration parameters for output No. 1
100h
Yes
0÷2
“
Mode
” parameter in “
Outputs settings
” submenu for output 1;
0
– inactive (always OPEN)
1
– normally OPEN (N.O.)
2
– normally CLOSED (N.C.)
101h
Yes
0÷1
“
Logic func.
” parameter in “
Outputs settings
” submenu for output 1;
0
–
OR
;
1
–
AND
102h
Yes
0÷4
“
Channel 1
” parameter in “
Outputs settings:source
” submenu for
output 1;
0
–
inactive
1
–
alarm 1
2 – alarm 2
3 – alarm 1 or 2
4 – alarm 1 and 2
103h
Yes
0÷4
“
Channel 2
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
104
Yes
0÷4
“
Channel 3
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
105
Yes
0÷4
“
Channel 4
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
106
Yes
0÷4
“
Channel 5
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
107
Yes
0÷4
“
Channel 6
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
108
Yes
0÷4
“
Channel 7
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
109
Yes
0÷4
“
Channel 8
” parameter in “
Outputs settings:source
” submenu for
output 1; registry description like for “
Channel 1
” (see register 102h).
10A
Yes
0÷9999
“Close delay
” parameter in “
Outputs settings
” submenu for output 1
10B
Yes
0÷9999
“
Open delay”
parameter in
“Outputs settings”
submenu output 1
10C
Yes
0÷9999
“
Closed hold time”
parameter in
“Outputs settings”
submenu for
output 1.
10D
Yes
0÷9999
“
Open hold time”
parameter in
“Outputs settings”
submenu for
output 1.