User manual - DATA RECORDER SRD-99 and cooperating software
Register Write
Range
Register description
4Ah
Yes
Character
“
Name
” parameter in “
Inputs settings
” submenu for channel 1;
Higher byte – character No. 7; Lower byte – character No. 8
4Bh
Yes
Character
“
Name
” parameter in “
Inputs settings
” submenu for channel 1;
Higher byte – character No. 9; Lower byte – 0
4Ch
Yes
Character
“
Unit
” parameter in “
Inputs settings
” submenu for channel 1;
Higher byte – character No. 1; Lower byte – character No. 2
4Dh
Yes
Character
“
Unit
” parameter in “
Inputs settings
” submenu for channel 1;
Higher byte – character No. 3; Lower byte – character No. 4
Register from 50h to 5Dh
Parameters in “
Inputs settings
” submenu for channel 2; registry
description like for channel 1 (see registers 40h to 4Dh).
Register from 60h to 6Dh
Parameters in “
Inputs settings
” submenu for channel 3; registry
description like for channel 1 (see registers 40h to 4Dh).
Register from 70h to 7Dh
Parameters in “
Inputs settings
” submenu for channel 4; registry
description like for channel 1 (see registers 40h to 4Dh).
Register from 80h to 8Dh
Parameters in “
Inputs settings
” submenu for channel 5; registry
description like for channel 1 (see registers 40h to 4Dh).
Register from 90h to 9Dh
Parameters in “
Inputs settings
” submenu for channel 6; registry
description like for channel 1 (see registers 40h to 4Dh).
Register from A0h to ADh
Parameters in “
Inputs settings
” submenu for channel 7; registry
description like for channel 1 (see registers 40h to 4Dh).
Register from B0h to BDh
Parameters in “
Inputs settings
” submenu for channel 8; registry
description like for channel 1 (see registers 40h to 4Dh).
Alarm configuration parameters for channel No. 1
C0h
Yes
0÷1
"
AL1 mode
"
parameter in “
Inputs settings
” submenu for channel 1;
0
– under threshold;
1
– over threshold
C1h
Yes
-9999÷9999
"
Threshold 1
"
parameter in “
Inputs settings
” submenu
for channel 1;
C2h
Yes
-9999÷9999
"
Hysteresis 1
"
parameter in “
Inputs settings
” submenu
for channel 1;
C3h
Yes
0÷1
"
AL2 mode
"
parameter in “
Inputs settings
” submenu for channel 1;
0
– under threshold;
1
– over threshold
C4h
Yes
-9999÷9999
"
Threshold 2
"
parameter in “
Inputs settings
” submenu
for channel 1;
C5h
Yes
-9999÷9999
"
Hysteresis 2
"
parameter in “
Inputs settings
” submenu
for channel 1;
Register from C8h to CDh
Alarm parameters in “
Inputs settings
” submenu for channel 2;
registry description like for channel 1 (see registers C0h to C5h).
Register from D0h to D5h
Alarm parameters in “
Inputs settings
” submenu for channel 3;
registry description like for channel 1 (see registers C0h to C5h).
Register from D8h to DDh
Alarm parameters in “
Inputs settings
” submenu for channel 4;
registry description like for channel 1 (see registers C0h to C5h).
67