background image

Model

Amps

Output Pressure

Maximum

PSI

0

10

20

30

40

50

2825SS

9.8

10

8.5

8.0

7.5

7.0

6.0

80

For parts or assistance, call Simer Customer Service at 

1-800-468-7867

Installation / Operation 

5

Hazardous pressure. Do not shut off the 

hose or the sprinklers while the pump is running. The 
hose or  sprinkler head may explode.

PIPING

Both the suction and discharge ports are tapped for 

1” NPT threads. If using hoses, use hose adapters. See 

Figure 2. Do not use a hose on the suction if pumping 

from lakes, streams or ponds. The hose will collapse and 

cause pump failure. Install a strainer with a foot valve on 

the end of the suction line. Inspect and clean the strainer 

frequently (Figure 4). 

NOTICE: An air leak in the suction pipe may draw air in 

although no water leaks out. Make sure there are no air 

leaks or air pockets in the suction pipe.

PRIMING/OPERATION

NOTICE: Do not run the pump dry. Running the pump 

without water can damage the impeller and may damage 

the seal, causing leaking or flooding, and will void  

warranty.
All suction connections must be airtight. Make sure the 

suction lift is not more than 25 feet (7.6M). Fill the pump 

body through the priming port before starting the pump. 

Start the pump; it should pump water in under 10 min-

utes (depending on the length of the suction hose and 

the height of the pump above water).

PREPARING TO START THE PUMP 

(REFER TO FIGURE 5)

Risk of burns. Never run pump dry. 

Running the pump without water may cause the pump to 
overheat, damaging the seal and possibly causing burns 
to persons handling the pump. Fill the pump with water 
before starting.

Hazardous Pressure. Never run the pump 

against closed discharge. To do so can boil water inside 

pump, causing hazardous pressure in unit, risk of explo-

sion and possibly scalding persons handling pump.
1.  Remove the priming plug from the priming tee and 

fill the pump. Fill all piping between the pump and 

the well and make sure that all piping in the well is 

full. If you have also installed a priming tee in the 

suction piping, remove the plug from the tee and fill 

the suction piping. See Figure 5.

Water faucet

Connect the pump inlet
to the water faucet
for use with sprinklers.

3942 0401

Hose
adapters

Figure 3: Connect pump to a spigot for use with sprin-
klers. Connect with adapters supplied with pump

115V, GFCI
Protected,
Grounded 
Outlet Box

Discharge Line
(Garden Hose or
Rigid Pipe)

Suction Line
(Garden Hose or
Rigid Pipe)

Foot valve with
strainer (clean 
frequently)

Hose
Adapters

3940 0401

Figure 4: Strainer and foot valve installation

Remove the 
plug and
fill the pump 
and the piping 
through the 
priming tee.

3939 0401

Figure 5: Prime the Pump

Содержание PORTABLE UTILITY/SPRINKLER PUMP 2825SS

Страница 1: ...ce Call 1 800 468 7867 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages...

Страница 2: ...for potable water always dis in fect the well and test the water for purity before using Check with your local health de part ment for testing pro ce dures 7 Complete pump and piping must be protected...

Страница 3: ...O NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If yo...

Страница 4: ...is completes the well plumbing for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections BOOSTING CITY WATER PRESSURE Hazardous pressure Never run the pump against...

Страница 5: ...gth of the suction hose and the height of the pump above water PREPARING TO START THE PUMP REFER TO FIGURE 5 Risk of burns Never run pump dry Running the pump without water may cause the pump to overh...

Страница 6: ...ine with soapy water or shaving cream 3 Leaking foot valve 3 Replace foot valve 4 Pipe size is too small 4 Re pipe using size of suction and discharge ports on pump Pump has lost prime through In inst...

Страница 7: ...Pump Body 1 111P1190 8 Flange 1 101P1290 9 Intermediate Support 1 721S4460 10 Handle with Handle Grip 1 751S8960 11 Washer Handle 1 121P1500 12 Screw Handle 1 121P1600 13 Lock Nut Handle 1 121P0020 14...

Страница 8: ...t avant d utiliser l eau la faire analyser pour s assurer de sa puret Pour proc der l analyse de l eau s adresser au Service de sant de la municipalit 7 La pompe et les tuyauteries doivent tre prot g...

Страница 9: ...illant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gou...

Страница 10: ...syst me S assurer que tous les raccords du tuyau d aspiration sont bien tanches aussi bien l air qu l eau Si le tuyau d aspiration aspire de l air la pompe ne pompera pas l eau du puits 3 R gler la h...

Страница 11: ...lle ris que de surchauffer ses joints risquent d tre endommag s et les personnes qui la manipuleront risquent de se br ler Remplir la pompe d eau avant de la d marrer Pression dangereuse Risque d expl...

Страница 12: ...du tuyau d aspiration 3 Parce que le clapet de pied fuit 3 Remplacer le clapet de pied 4 Parce que le diam tre du tuyau 4 Remplacer le tuyau par un dont le diam tre est le m me que celui est trop peti...

Страница 13: ...101P1290 9 Support interm diaire 1 721S4460 10 Poign e 1 751S8960 11 Rondelle de la poign e 1 121P1500 12 Vis de la poign e 1 121P1600 13 crou de la poign e 1 121P0020 14 D flecteur d eau 1 102P0540 1...

Страница 14: ...na prueba de la pureza de agua antes de usarla Verifique los procedimientos de prueba con su depar tamento de sanidad local 7 Tanto la bomba como los tubos deben estar protegidos contra heladas Las he...

Страница 15: ...loacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y s...

Страница 16: ...completar la tuber a del pozo para su nueva bomba de chorro para pozos poco profundos Pase a la p gina 6 para la informaci n sobre las conexiones de la tuber a de descarga y del tanque REFUERZO DE LA...

Страница 17: ...ocar sobrecalentamiento puede da ar el sello y posiblemente provoque quemaduras a las perso nas que la est n manipulando Llene la bomba con agua antes de encenderla Presi n peligrosa Nunca haga marcha...

Страница 18: ...bos del tama o de los orificios de demasiado peque o aspiraci n y de descarga en la bomba La bomba ha perdido cebadura debido a En instalaciones que ya est n en uso 1 Fugas de aire 1 Verifique todas l...

Страница 19: ...Brida 1 101P1290 9 Soporte intermedio 1 721S4460 10 Manija 1 751S8960 11 Arandela Manija 1 121P1500 12 Tornillo Manija 1 121P1600 13 Contratuerca Manija 1 121P0020 14 Deflector del agua 1 102P0540 15...

Страница 20: ......

Отзывы: