Simer PORTABLE UTILITY/SPRINKLER PUMP 2825SS Скачать руководство пользователя страница 6

Operation 6

For parts or assistance, call Simer Customer Service at 

1-800-468-7867

2.  Replace all fill plugs. 
3.  Power on! Start the pump. If you don’t have water 

after 2 or 3 minutes, stop the pump and remove the 

fill plugs. Refill the pump and piping. You may have 

to repeat this several times in order to get all of the 

trapped air out of the piping. A pump lifting water 25’ 

may take as long as 15 minutes to prime.

Congratulations on a successful installation.
If you were unsuccessful, please refer to the 

Troubleshooting section (below) or call our customer ser-

vice technical staff at 1-800-468-7867.

Troubleshooting 

   SYMPTOM 

POSSIBLE CAUSE(S) 

CORRECTIVE ACTION

  Motor will not run 

Fuse is blown or circuit breaker tripped 

DISCONNECT POWER;Replace fuse or reset circuit breaker.

  Motor runs hot and  

Voltage is too low 

Check voltage being supplied to the pump. 

  the overload kicks  

  off or the does not  

  run and only hums.

  Motor runs but no  

Pump during  new installation did  

In new installation: 

  water is delivered* 

not pick up prime through:  

    

  1. Improper priming  

  1. Re-prime according to instructions. 

    

  2. Air leaks 

  2. Check all connections on suction line, with soapy water or 

   

 

      shaving cream.

    

  3. Leaking foot valve 

  3. Replace foot valve.

    

  4. Pipe size is too small 

  4. Re-pipe using size of suction and discharge ports on pump.

    

Pump has lost prime through: 

In installation already in use: 

     

  1. Air leaks 

  1. Check all connections on suction line and shaft seal with soapy water. 

    

  2. Water level below suction pipe inlet 

  2. Lower suction line into water and re-prime. If receding water level  

    

  

      in well exceeds 25’ (7.6M), a deep well pump is needed.

   

Impeller is plugged 

Clean impeller.

   

Foot valve is stuck shut  

Replace the foot valve.

    

Pipes are frozen 

Thaw pipes.

    

Foot valve and/or strainer are  

Raise the foot valve and/or strainer above bottom of water source. 

    

buried in sand or mud 

Clean foot valve and strainer.

  *Pump does not  

Water being pumped is lower than  

A deep well jet will may needed if the water being pumped is more than   

  deliver water to full  

estimated 

25’ (7.6M) depth to water.

  capacity 

Steel piping (if used) is corroded or  

Replace with plastic pipe where possible, otherwise with new steel pipe. 

   

limed, causing excess friction

    

Piping is too small in size 

Re-pipe using size of suction and discharge ports on pump.

   

Pump not being supplied with  

Add additional well points.

   

enough water 

* (Note: Stop pump; 

then check prime 

before looking 

for other causes. 

Unscrew priming 

plug and see if water 

is in priming hole).

Содержание PORTABLE UTILITY/SPRINKLER PUMP 2825SS

Страница 1: ...ce Call 1 800 468 7867 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages...

Страница 2: ...for potable water always dis in fect the well and test the water for purity before using Check with your local health de part ment for testing pro ce dures 7 Complete pump and piping must be protected...

Страница 3: ...O NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If yo...

Страница 4: ...is completes the well plumbing for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections BOOSTING CITY WATER PRESSURE Hazardous pressure Never run the pump against...

Страница 5: ...gth of the suction hose and the height of the pump above water PREPARING TO START THE PUMP REFER TO FIGURE 5 Risk of burns Never run pump dry Running the pump without water may cause the pump to overh...

Страница 6: ...ine with soapy water or shaving cream 3 Leaking foot valve 3 Replace foot valve 4 Pipe size is too small 4 Re pipe using size of suction and discharge ports on pump Pump has lost prime through In inst...

Страница 7: ...Pump Body 1 111P1190 8 Flange 1 101P1290 9 Intermediate Support 1 721S4460 10 Handle with Handle Grip 1 751S8960 11 Washer Handle 1 121P1500 12 Screw Handle 1 121P1600 13 Lock Nut Handle 1 121P0020 14...

Страница 8: ...t avant d utiliser l eau la faire analyser pour s assurer de sa puret Pour proc der l analyse de l eau s adresser au Service de sant de la municipalit 7 La pompe et les tuyauteries doivent tre prot g...

Страница 9: ...illant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gou...

Страница 10: ...syst me S assurer que tous les raccords du tuyau d aspiration sont bien tanches aussi bien l air qu l eau Si le tuyau d aspiration aspire de l air la pompe ne pompera pas l eau du puits 3 R gler la h...

Страница 11: ...lle ris que de surchauffer ses joints risquent d tre endommag s et les personnes qui la manipuleront risquent de se br ler Remplir la pompe d eau avant de la d marrer Pression dangereuse Risque d expl...

Страница 12: ...du tuyau d aspiration 3 Parce que le clapet de pied fuit 3 Remplacer le clapet de pied 4 Parce que le diam tre du tuyau 4 Remplacer le tuyau par un dont le diam tre est le m me que celui est trop peti...

Страница 13: ...101P1290 9 Support interm diaire 1 721S4460 10 Poign e 1 751S8960 11 Rondelle de la poign e 1 121P1500 12 Vis de la poign e 1 121P1600 13 crou de la poign e 1 121P0020 14 D flecteur d eau 1 102P0540 1...

Страница 14: ...na prueba de la pureza de agua antes de usarla Verifique los procedimientos de prueba con su depar tamento de sanidad local 7 Tanto la bomba como los tubos deben estar protegidos contra heladas Las he...

Страница 15: ...loacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y s...

Страница 16: ...completar la tuber a del pozo para su nueva bomba de chorro para pozos poco profundos Pase a la p gina 6 para la informaci n sobre las conexiones de la tuber a de descarga y del tanque REFUERZO DE LA...

Страница 17: ...ocar sobrecalentamiento puede da ar el sello y posiblemente provoque quemaduras a las perso nas que la est n manipulando Llene la bomba con agua antes de encenderla Presi n peligrosa Nunca haga marcha...

Страница 18: ...bos del tama o de los orificios de demasiado peque o aspiraci n y de descarga en la bomba La bomba ha perdido cebadura debido a En instalaciones que ya est n en uso 1 Fugas de aire 1 Verifique todas l...

Страница 19: ...Brida 1 101P1290 9 Soporte intermedio 1 721S4460 10 Manija 1 751S8960 11 Arandela Manija 1 121P1500 12 Tornillo Manija 1 121P1600 13 Contratuerca Manija 1 121P0020 14 Deflector del agua 1 102P0540 15...

Страница 20: ......

Отзывы: