Simado GFXD1111S Скачать руководство пользователя страница 36

V

ersion 3, January 2010

MATRIX TELECOM PVT. LTD.

MATRIX TELECOM PVT. LTD.

MATRIX TELECOM PVT. LTD.

MATRIX TELECOM PVT. LTD.

MATRIX TELECOM PVT. LTD.

Corporate Office:

394-GIDC, Makarpura, Vadodara - 390010, India.
Tel.:+91 265 2630555, Fax: +91 265 2636598
E-mail:  [email protected]

Factory:

39-GIDC, Waghodia - 391760, Dist. Vadodara, India.
Tel.: +91 2668 262056/57

Technical Support:

Tel.: +91 2668 263172/73, Fax: +91 2668 262631
E-mail:  [email protected]

www.MatrixTeleSol.com

Содержание GFXD1111S

Страница 1: ...SIMADO GFXD1111S Quick Start...

Страница 2: ......

Страница 3: ...SIMADO GFXD1111S SIMADO GFXD1111S SIMADO GFXD1111S SIMADO GFXD1111S SIMADO GFXD1111S Fixed Cellular Terminal and Router with Data Port Quick Start...

Страница 4: ...her GSM or CDMA SIM Card is installed in the GSM Port and RUIM Card is installed in the CDMA Port of the gateway Consider SIM as RUIM if CDMA module is installed in the gateway Call Divert feature wil...

Страница 5: ...PWR are as shown in the figure below These LEDs indicate the status of the ports various events occurring on the ports and also the error conditions Ready Network FXS FXO Power Applications of SIMADO...

Страница 6: ...RJ 11 GFXD1111S FSK DTMF Telephone Instrument COM Case 2 SIMADO GFXD1111S as Stand alone Mobile FXS Mode PSTN GSM CDMA Network FXO Port GSM CDMA FXS Port RJ 11 GFXD1111S COM Case 3 SIMADO GFXD1111S co...

Страница 7: ...T2 Tn S1 S2 Sn COM Case 5 SIMADO GFXD1111S interfaced with FXO Port of PBX Mobile FXS Mode PSTN GSM CDMA Network FXO Port GSM CDMA FXS Port RJ 11 GFXD1111S PBX T1 T2 Tn S1 S2 Sn COM Case 6 SIMADO GFXD...

Страница 8: ...ify Package Contents Before installing SIMADO GFXD1111S verify the package contents The Sales Kit of SIMADO GFXD1111 contains SIMADO GFXD1111 with Antenna TNC Male Quick Start CD containing System Man...

Страница 9: ...e trunk line from PSTN 4 One computer for programming and generating reports on HyperTerminal 5 Connection to Mains power Installing SIMADO GFXD1111S Precautions and Safety Instructions Take proper pr...

Страница 10: ...Card of the service provider in the SIM Card Slot of GFXD1111 Connect AC Mains input of GFXD1111 to the AC Mains Socket and Power ON the system Follow the steps given below to connect GFXD1111S Place...

Страница 11: ...d is absent or deactivated or SIM PIN is faulty or SIM PUK is required Once the system is switched ON it attains the normal working position in few minutes During Normal Functioning Following table sh...

Страница 12: ...using communication port follow the steps given below Program the SIMADO GFXD1111S in Report Generation mode using command 231 3 Prepare a text file txt containing programming commands in the notepad...

Страница 13: ...er the programming command Dial 00 to exit the programming mode SE can reset SA password from the SE mode For more details please refer System Security Passwords feature in the System Manual Refer Pro...

Страница 14: ...FXD1111S When GFXD1111S receives this SMS it will execute the commands in the SMS and thus configure the system Refer Programming GFXD1111S using SMS in the System Manual for more details Programming...

Страница 15: ...hould take above steps to change the SIM PIN of the SIM card in case SIM protection of SIM card is enabled and SIM PIN of SIM Card and GFXD1111S is different else GFXD1111S will not initialize Use fol...

Страница 16: ...er ON the SIM inserted in GFXD1111S will start searching for the network and will register automatically with the available network However GFXD1111S enables you to select the network to register your...

Страница 17: ...equired if 3G module is installed in SIMADO GFXD1111S Refer Mobile Network Selection feature in System Manual for more details You can check the strength of network signals on the LCD of telephone ins...

Страница 18: ...rvices feature in System Manual for more details Receive Gain Use following command to program the receive gain of the mobile port 271 Receive Gain Where Receive Gain range is from 1 to 5 where 1 is m...

Страница 19: ...Port 211 Code Where Code Meaning 0 Disable 1 Enable By default the FXO port is enabled Dial Type Use following command to program the dial type for the FXO Port 212 Code Where Code Meaning 1 Tone DTMF...

Страница 20: ...l for more details Ring Cadence OFF Timer Use following command to program the ring cadence off timer for FXO Port 215 Ring Cadence Off Timer Where Ring Cadence Off Timer is from 1 to 9 seconds By def...

Страница 21: ...by the PSTN network Use following command to enable disable disconnect tone detection on FXO Port 320 Code Where Code Meaning 0 Disable 1 Enable By default it is enabled Use following command to prog...

Страница 22: ...ets delayed by 2 3 seconds this delay can be avoided by using CLI type None Replacing by DTMF digits in CLI Use following command to program the digits which will replace in the CLI 301 Number String...

Страница 23: ...eversal is selected Use following command to program Open Loop Disconnect Timer on FXS Port 249 Open Loop Disconnect Timer Where Open Loop Disconnect timer is from 001 to 999 ms By default it is 500 m...

Страница 24: ...25on 0 25off 20 New Zealand 400 cont 400 0 5on 0 5off 400 0 25on 0 25off 21 Phillippines 425 cont 480 620 0 5on 0 5off 480 620 0 25on 0 25off 22 Poland 425 cont 425 0 5on 0 5off 425 0 5on 0 5off 23 P...

Страница 25: ...2 0 4 2 25 USA Canada 25 2 4 Cadence in second Code Country Frequency Hz By default Code 09 i e India is selected Default values for all ring types for all the countries as per ETSI standard is progra...

Страница 26: ...By default SE Password is 1234 Therefore Reverse of SE Password is 4321 GFXD1111S will restart as soon as command to load the default configuration is issued Ensure that the SIMADO GFXD1111S is set t...

Страница 27: ...XD1111S does not get registered to GSM network Ans Check whether the SIM card is properly inserted and it is activated Check SIM PIN Check the availability of good GSM signal Check the connectivity of...

Страница 28: ...nual Network Selection In CDMA module there is an Electronic Serial Number viz ESN which is similar to the IMEI number of GSM module Features at Glance Sr Description Feature Commands 1 To know the Si...

Страница 29: ...omatic number translation table 290 Port Type To print FXO Mobile automatic number translation 546 Port Type Call Duration Display To view the duration type of the last call 610 Call Type To clear dur...

Страница 30: ...rotation of call landing 412 Flag To program time zone index 421 Time Zone Index Start Time End Time To program service provider sequence 422 Time Zone Index S1 SP2 To set default the Time Zone w ise...

Страница 31: ...umber string 162 Mobile Network Selection To select netw ork selection mode 331 M ode To select netw ork operator number w ith priority 332 Priority Code To clear netw ork operator number 332 Priority...

Страница 32: ...dex Date M onth To delete particular concessional date 539 Index To delete all concessional dates 539 00 Database2 for FXO Port To program an area code 511 Area Code Index Area Code To program normal...

Страница 33: ...eply 131 Code To program Frw d Calls to FXO Port Destination Number 132 Destination Number To clear Frw d Calls to FXO Port Destination Number 132 To program Frw d Calls to FXO Port When No Reply Time...

Страница 34: ...Timer for Mobile Port 275 Pause Timer To program DTMF Dialing Method for Mobile Port 273 Code Port Released Timer To program Port Release Timer 256 Port Release Timer Programming the System through C...

Страница 35: ...ogram the inter digit w ait timer 226 Duration To program DTMF out dial ON time for Mobile FXO Port 241 Code To program Inter Digit Pause Time for Mobile FXO Port 242 Code To program DTMF Out Dial Lev...