CLI type 'None' is selected when the exchange does not support any type of
CLI or user does not want to detect the CLI. Detecting CLI takes time and
thus the routing of call gets delayed by 2-3 seconds, this delay can be avoided
by using CLI type = 'None'.
Pause Timer:
Use following command to program Pause Timer for FXO Port:
217-Pause Timer-#*
Where,
Pause Timer is from 1 to 9 seconds.
By default, Pause Timer is 2 seconds for the FXO Port.
Example:
If number string to be dialed out on the FXO port is PPP234 and
pause timer is programmed as 3 seconds then GFXD1111S will dial out digit
2 after P+P+P seconds i.e. 3+3+3=9 seconds.
(Refer 'Port Parameters-FXO' feature in System Manual for more details)
Ring Cadence OFF Timer:
Use following command to program the ring cadence off timer for FXO Port:
215-Ring Cadence Off Timer-#*
Where,
Ring Cadence Off Timer is from 1 to 9 seconds.
By default, it is 4 seconds.
Answer Supervision on FXO Port:
Use following command to program the Answer Supervision Signal on FXO
port:
213-Answer Supervision Signal-#*
Where,
Answer Supervision Signal
Meaning
0
None
1
Battery Revrsal
2
12/16 KHz
By default, Answer Supervision Signal is None.
It is recommended to set the same answer signaling on FXO port as
supported by the CO (PSTN) network else the system might fail to detect
the correct signaling on the FXO port resulting in inaccurate billing etc.
(Refer 'Port Parameters- FXO' in System Manual for more details)
Disconnect Supervision:
Use following command to program the disconnect signal on the FXO Port:
218-Disconnect Signal-#*