HGW 1033-3
WIRELESS HANDHELD OPERATING PANEL
10 Help with Disruptions/Troubleshooting
Problem
Cause
Solution
HGW does not function,
display remains dark,
HGW does not turn on
HGW not charging from the base
station
Check whether the base station is
powered correctly.
Battery empty
Mount HGW in the base station. The
HGW is then charged.
Battery defective
Return the device to SIGMATEK.
See chapter 13.3 Repair
Defective backlight
Call SIGMATEK customer service.
Panel in transport mode
See chapter 11 Transport/Storage
HGW functional range limited
Emergency stop triggered
See chapter 16.2.6 Emergency Stop.
Touch screen malfunction
Operation using gloves
Operate the HGW with the fingers
directly or with suitable gloves.
Offset of touch screen press-
points
Touch screen uncalibrated
Recalibrate the touch screen See
chapter 13.2.1 Calibrating the Touch
Screen
Unintended triggering of the
emergency stop
Wireless connection failure due to
distance from base station
Observe the warning for weak
WLAN signal
Internal device error
Please return the device for.
Undesired triggering of the
touch screen
Panel placed with touch screen face
down
Lay the panel on its base.
Something has been placed on the
touch screen
Remove the object from the touch
screen.
Device does not go into
transport mode
Device charging
Disconnect the device from all
supplies
Page 66
03.03.2021
Содержание HGW 1033
Страница 28: ...HGW 1033 3 WIRELESS HANDHELD OPERATING PANEL 5 Interfaces 5 1 Connections Bottom Page 26 03 03 2021 ...
Страница 31: ...WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 5 2 Rear Connectors 03 03 2021 Page 29 ...
Страница 36: ...HGW 1033 3 WIRELESS HANDHELD OPERATING PANEL 5 4 WLAN Page 34 03 03 2021 ...
Страница 63: ...WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 03 03 2021 Page 61 ...