![SIGMATEK HGW 1033 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/sigmatek/hgw-1033/hgw-1033_operating-manual_1268127022.webp)
HGW 1033-3
WIRELESS HANDHELD OPERATING PANEL
Status LEDs
3x front (controllable via application)
1x back (boot status/controllable via application)
1x power switch (shows power and charge status)
Signal generator
yes (at least 83 dB at 30 cm)
Real-time clock
yes (buffered circa 3 days via internal battery)
Temperature sensors
4 (2x LP, 1x CPU, 1x battery)
Cooling
passive (fanless)
Coupling display
7-segment LED, two-digit
Input voltage measurement
yes
4.2 Electrical Requirements
Charging voltage
Magnetic connector
typ19 V DC
m15 V DC
m24 V
Protection class
III
Charging current
via base station: up to 2.5 A at 15.5 V
USB Host current load
maximum 0.5 A
INFORMATION
The specified charging time applies to the charging process when the
panel is not simultaneously in use. If the device is in use while charging,
the charging time can increase.
To protect the battery, the intelligent charging circuit monitors the
ambient temperature. For this reason, the charging time can be
extended at high ambient temperatures.
The specified current consumption applies to the status without
connected peripherals (USB stick ...).
Page 20
03.03.2021
Содержание HGW 1033
Страница 28: ...HGW 1033 3 WIRELESS HANDHELD OPERATING PANEL 5 Interfaces 5 1 Connections Bottom Page 26 03 03 2021 ...
Страница 31: ...WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 5 2 Rear Connectors 03 03 2021 Page 29 ...
Страница 36: ...HGW 1033 3 WIRELESS HANDHELD OPERATING PANEL 5 4 WLAN Page 34 03 03 2021 ...
Страница 63: ...WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 03 03 2021 Page 61 ...