![SIGMATEK HGW 1033 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/sigmatek/hgw-1033/hgw-1033_operating-manual_1268127053.webp)
WIRELESS HANDHELD OPERATING PANEL
HGW 1033-3
Number
Message
Definition
Cause/Solution
53
FLOATING POINT ERROR
An error has occurred
during a floating-point
operation.
60
DIAS-RISC-ERROR
Error from the Intelligent
DIAS Master.
Restart, report error to SIGMATEK.
64
INTERNAL ERROR
An internal error has
occurred, all applications
are stopped.
Restart, report error to SIGMATEK.
65
FILE ERROR
An error has occurred
during a file operation.
66
DEBUG ASSERTION
FAILED
Internal error
Restart, report error to SIGMATEK.
67
REALTIME RUNTIME
The total duration of all
real-time objects exceeds
the maximum time; the
time cannot be
configured. 2 ms for 386
CPUs, 1 ms for all other
CPUs
Solution:
n
Optimize the application's real-
time task (RtWork).
n
Reduce the clock time for the
real-time task of all objects.
n
Correct application errors
n
CPU is overloaded in real-time
=> use a higher capacity CPU.
68
BACKGROUND RUNTIME
The total time for all
background objects
exceeds the maximum
time; the time can be
configured using 2
system variables: -
BTRuntime: -
SWBTRuntime: pre-
selected value for the
runtime counter
Solution:
n
Optimize the application's
background task (background)
n
Use higher capacity CPU
n
Set SWBTRuntime correctly
70
C-DIAS ERROR
A connection error with a
C-DIAS module has
occurred.
Cause:
n
The cause of the error is
documented in the log file
Solution:
n
This depends on the cause
03.03.2021
Page 51
Содержание HGW 1033
Страница 28: ...HGW 1033 3 WIRELESS HANDHELD OPERATING PANEL 5 Interfaces 5 1 Connections Bottom Page 26 03 03 2021 ...
Страница 31: ...WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 5 2 Rear Connectors 03 03 2021 Page 29 ...
Страница 36: ...HGW 1033 3 WIRELESS HANDHELD OPERATING PANEL 5 4 WLAN Page 34 03 03 2021 ...
Страница 63: ...WIRELESS HANDHELD OPERATING PANEL HGW 1033 3 03 03 2021 Page 61 ...