2.8.4 FUNCTION
SET-UP
You can select the desired functions as detailed in the following table.
Table 19: Functions
Function
Setting
Alarm Latch
•
Yes: Enable Alarm latching.
•
No: Disable Alarm latching (default).
Auxiliary Relay**
•
Yes: Activate Auxiliary Relay at Warning level.
•
No: Activate Auxiliary Relay at Alarm level (default).
Automatic BIT
•
Yes: Perform Automatic & Manual Bit (default).
•
No: Perform Manual Bit only.
Alarm BIT
•
Yes: Successful Manual Bit activates the Alarm Relay
for approximately 3 seconds (default).
•
No: Successful Manual Bit does not activate the Alarm
Relay.
Auxiliary BIT**
•
Yes: Successful Manual Bit activates the Auxiliary Relay
for approximately 3 seconds (default).
•
No: Successful Manual Bit does not activate the
Auxiliary Relay.
EOL**
•
Yes: Auxiliary Relay is used as End of Line.
•
No: Auxiliary Relay operates in accordance with
Function 2 and 5 (default).
Note
: ** only available in Model 3600I-4XXXX and 5XXXX
2.8.5 HEATED
OPTICS
The heated optics can be defined as one of the following modes:
•
Heated
Mode
•
OFF: Not operated
•
On:
Continuously
•
AUTO: Per temperature change
In AUTO mode, the default HEAT ON setting is 41°F (5°C). Heating stops when the
temperature is 27°F (15°C) above the start temperature.
You can define the start temperature below which the window will be heated. The
temperature can be defined between 32°F and 122°F (0°C to 50°C).