Scale parameters and functions
8.11 DR 10 load cell parameters
SIWAREX WP231
98
Manual, 07/2014, A5E31238908A-02
8.11
DR 10 load cell parameters
8.11.1
Overview
The parameters of the analog load cells must be checked prior to the automatic calibration
and modified if necessary. Only the parameters identified by bold font and asterisk (*) need
be entered.
Procedure
●
Check the parameters and modify them as required
●
Transfer the data record to the scales
●
Adjust the scales
Table 8- 10 Assignment of data record 10
Variable
Note
Type
Length
(bytes)
Rw
Default Min.
Max.
Modbus
registers
Data record
number
Contains no. of data record
USHORT
2
r
10
-
-
1400
Length
Data record length information
USHORT
2
r
44
-
-
1401
Application
Information about which applica-
tion the DR belongs to
USHORT
2
r
101
-
-
1402
Version identi-
fier
Information on current data record
version
USHORT
2
r
1
1
65635
1403
Number of load
cells
1)
Number of analog load cells (in-
ternal variable)
USHORT
2
rw
1
1
6
1404
(Page 100)
50/60 Hz toggling
USHORT
2
rw
0
0
1
1405
(Page 100)
1)
Number of support points
USHORT
2
rw
0
0
8
1406
Reserve
USHORT
2
rw
0
0
0
1407
(Page 100)
1)
Characteristic value of the load
cell (n) [mV/V], the mean value is
used if there is more than one cell.
FLOAT
4
rw
2
>0.1
10
1408
Zero point
offset
1)
Zero point offset in uV/V, the
mean value is used if there is
more than one cell. (internal varia-
ble)
FLOAT
4
rw
0
-1000
1000
1410
(Page 100)
1)
Rated load of a load cell
FLOAT
4
rw
60
-
-
1412
Reserve
Reserve
FLOAT
4
rw
0
-
-
1414
Reserve
Reserve
FLOAT
4
rw
0
-
-
1416
Reserve 2
Reserve
SHORT
2
rw
0
-
-
1418
Reserve 3
Reserve
USHORT 2
rw
0
-
-
1419
Reserve 4
Reserve
FLOAT
4
rw
0
-
-
1420
1)
Parameter for calculation of calibration points with theoretical calibration
Содержание SIWAREX WP231
Страница 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Страница 24: ...Application planning 4 2 Parameter assignment options SIWAREX WP231 24 Manual 07 2014 A5E31238908A 02 ...
Страница 108: ...Scale parameters and functions 8 15 DR 15 tare settings SIWAREX WP231 108 Manual 07 2014 A5E31238908A 02 ...
Страница 131: ...Scale parameters and functions 8 26 DR 48 date and time 2 for Modbus SIWAREX WP231 Manual 07 2014 A5E31238908A 02 131 ...
Страница 132: ......
Страница 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Страница 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Страница 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...