Commissioning
7.5 5 minute quick start with the operator panel and the Ready-for-Use software
SIWAREX WP231
50
Manual, 07/2014, A5E31238908A-02
7.5.6
Calibrating the scale automatically
The scale can also be calibrated without weights. To do this, it is necessary to enter data
specific to the load cells. In addition, it is essential that the scale is empty.
Figure 7-6
Quick start step 4b
The number of points of support corresponds with a silo, for example, to the number of
clamps or feet of the silo. A quadratic platform scale with a load cell at each corner has 4
support points. The characteristic values of the individual load cells are required to calculate
the average characteristic value of the cells.
The equation for the calculation is as follows:
(characteristic of cell 1 + characteristic of cell 2 + characteristic of cell n) / n
If the exact characteristic values are unknown, it is permissible to also use rounded-off
numbers (e.g. 1.0 mV/V, 2.0 mV/V). The nominal load of an individual load cell (not the
nominal load of the complete scale!) must subsequently be defined.
Содержание SIWAREX WP231
Страница 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Страница 24: ...Application planning 4 2 Parameter assignment options SIWAREX WP231 24 Manual 07 2014 A5E31238908A 02 ...
Страница 108: ...Scale parameters and functions 8 15 DR 15 tare settings SIWAREX WP231 108 Manual 07 2014 A5E31238908A 02 ...
Страница 131: ...Scale parameters and functions 8 26 DR 48 date and time 2 for Modbus SIWAREX WP231 Manual 07 2014 A5E31238908A 02 131 ...
Страница 132: ......
Страница 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Страница 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Страница 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...