Scale parameters and functions
8.18 DR 18 digital output control specifications
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
111
8.18
DR 18 digital output control specifications
8.18.1
Overview
If a digital output is defined in data record DR 7 for control with data record DR 18 (see
Assignment for digital output 0, 1, 2, 3 (Page 92)), you can control this output with data
record DR 18. Transfer is always for all four digital outputs. Only outputs which are
configured for control by DR 18 (see DR 7 interface parameters (Page 88)) are enabled or
disabled in accordance with the content of data record DR 18.
Procedure
●
Check or adapt the desired parameter settings of the digital outputs in data record 7
●
Define the value for digital output 0, 1, 2, 3
●
Transfer the data record to the scales
Table 8- 19 Assignment of data record 18
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
registers
Data record
number
Contains no. of data record USHORT 2
r
18
-
-
1608
Length
Data record length infor-
mation
USHORT 2
r
12
-
-
1609
Application
Information about which
application the DR belongs
to
USHORT 2
r
101
-
-
1610
Version identi-
fier
Information on current data
record version
USHORT 2
r
1
1
65635
1611
Specification for digital
output 0=1 -> DA0 output
enabled
(only applies if output is
assigned code 21, see
DR 7)
BIT
0
rw
0
0
1
1612.16
Specification for digital
output 1=1 -> DA1 output
enabled
(only applies if output is
assigned code 21, see
DR 7)
BIT
0
rw
0
0
1
1612.15
Specification for digital
output 2=1 -> DA2 output
enabled
(only applies if output is
assigned code 21, see
DR 7)
BIT
0
rw
0
0
1
1612.14
Specification for digital
output 3=1 -> DA3 output
enabled
(only applies if output is
assigned code 21, see
DR 7)
BIT
0
rw
0
0
1
1612.13
Содержание SIWAREX WP231
Страница 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Страница 24: ...Application planning 4 2 Parameter assignment options SIWAREX WP231 24 Manual 07 2014 A5E31238908A 02 ...
Страница 108: ...Scale parameters and functions 8 15 DR 15 tare settings SIWAREX WP231 108 Manual 07 2014 A5E31238908A 02 ...
Страница 131: ...Scale parameters and functions 8 26 DR 48 date and time 2 for Modbus SIWAREX WP231 Manual 07 2014 A5E31238908A 02 131 ...
Страница 132: ......
Страница 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Страница 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Страница 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...