Scale parameters and functions
8.2 DR 2 command code
SIWAREX WP231
64
Manual, 07/2014, A5E31238908A-02
8.2
DR 2 command code
DR 2 is a special data record used to transfer commands to the SIWAREX module by
SIWATOOL.
8.3
DR 3 calibration parameters
8.3.1
Overview
The calibration parameters need to be checked and if necessary modified for all scales.
The scale is basically defined by calibration parameters and calibration operation. A wire
jumper on the P-PR (Parameter Protection) terminals means that the DR 3 data can no
longer be changed (write-protected). All changes in data record 3 require service mode to be
switched on for the module. If service mode is not active, all parameter inputs are directly
rejected with an error.
Procedure
●
Check all parameters and modify them as required
●
Transfer the DR 3 data record from SIWATOOL to the scales
●
Adjust the scales
●
Transfer the DR 3 data record from the scales to SIWATOOL
Table 8- 1
Assignment of data record 3
Variable
Note
Type
Length
(bytes)
Read/write
protection
Default Min.
Max.
Modbus
registers
Data record
number
Contains no. of data record
USHORT
2
r
3
-
-
1000
Length
Data record length information
USHORT
2
r
192
-
-
1001
Application
Information on which application
the DR belongs to
USHORT
2
r
101
-
-
1002
Version
identifier
Information on the current data
record version
USHORT
2
r
1
1
65635
1003
Scale name
header
Maximum length and actual
length of string for scale name
UBYTE[2]
2
rwP
12.12
-
-
1004
(Page 68)
Scale name specified by user
CHAR[12]
12
rwP
" "
-
-
1005
Unit of
weight head-
er
Maximum length and actual
length of string for unit of weight
(e.g.: g, kg, t, ...)
UBYTE[2]
2
rwP
04.04
-
-
1011
(Page 68)
Unit of weight
CHAR[4]
4
rwP
"kg••"
-
-
1012
Содержание SIWAREX WP231
Страница 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Страница 24: ...Application planning 4 2 Parameter assignment options SIWAREX WP231 24 Manual 07 2014 A5E31238908A 02 ...
Страница 108: ...Scale parameters and functions 8 15 DR 15 tare settings SIWAREX WP231 108 Manual 07 2014 A5E31238908A 02 ...
Страница 131: ...Scale parameters and functions 8 26 DR 48 date and time 2 for Modbus SIWAREX WP231 Manual 07 2014 A5E31238908A 02 131 ...
Страница 132: ......
Страница 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Страница 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...