3-11
1020NFM-1D
Section 3
z
Seat O-Ring gasket to the pipe by pushing it off the corners of the transducer (Figure 8).
z
Install second transducer as described above but with front of transducer facing the Reference
Mounting Track Assembly.
z
Confirm installation is functional by completing flowmeter menu.
z
Install mounting track assembly covers and secure with eight screws.
NOTE: Transducer must be in contact with the mounting track reference stop (head of screw)
for accurate transducer positioning.
Figure 7
Front End of
Transducer
Transducer
Clamp
Figure 8
O-Ring
Reference Mounting
Track Assembly
Xdcr
Cable
Xdcr
Cable
Figure 9
Mounting Track
Covers
Securing
Screws