Connecting
5.4 Integrating the FST030 with Modbus system
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
36
Operating Instructions, 08/2017, A5E37367739-AC
④
Serial no.
Transmitter serial number
⑤
System revisions
System revision numbers; firmware (FW) and hardware (HW)
⑥
Power Supply
Power supply
⑦
Material/Version
Transmitter housing material and style (compact/remote)
⑧
Conduit / cable
entries
Type of conduit / cable entries
⑨
Enclosure IP /
Ambient temp.
Degree of protection / Ambient temperature
⑩
Year of Manufac-
ture
Manufacturing year
More detailed manufacturing date information is given in the serial
number (see sensor identification nameplate above)
⑪
SW function
Software function
⑫
Ch1
Communication interface on channel 1
⑬
Ch2
Ch3
Ch4
Ch5
Ch6
Input/output setup of channels 2 to 6, if ordered
⑭
WEEE symbol, see Disposal (Page 86)
⑮
Consult the Operating Instructions
⑯
C✓ / QR
-code
C-tick logo and product-specific QR-code
Figure 5-1
Transmitter nameplate example
See also
Approvals (Page 121)
Installation in hazardous areas (Page 20)
5.4
Integrating the FST030 with Modbus system
This chapter provides information on how to integrate the device in a point-to-point or
multidrop Modbus RTU network in non-hazardous or hazardous areas. Many details of
network design are beyond the scope of these operating instructions. The points below
provide an overview of the major design criteria. For further details contact Siemens.
If the device is integrated in a hazardous area, two flameproof conduit seals per device must
be installed; one at the device in the hazardous area and one in the non-hazardous area,
see System configuration (Page 37).