Description
3.2 Features
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
24
Operating Instructions, 08/2017, A5E37367739-AC
●
Full graphical local display
●
SensorFlash (SD card) for memory backup and documentation storage (certificates etc.)
●
USB service interface
●
Up to five input/output channels:
–
Channel 2: Signal output; can be parameterized for:
Current output (0/4-20 mA)
Pulse output
Frequency output
Alarm, status
–
Channels 3 and 4: Signal output
Current output (0/4-20 mA)
Pulse output
Frequency output
Alarm, status
Pulse or frequency redundancy mode (only channel 3)
–
Channels 3 and 4: Relay output
Alarm, status
–
Channels 3 and 4: Signal input; can be parameterized as:
Current input (4-20 mA)
Totalizer control (resetting of totalizers)
Zero adjustment
Freezing of process values
Forcing of outputs
–
Channels 5 and 6:
Temperature input (RTD)
●
Current, frequency, and pulse outputs with configurable fail safe mode
●
High immunity against process noise
●
Fast response to step changes in flow
●
High update rate (100 Hz) on process values