Modbus communication
A.9 Modbus holding registers tables
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
304
Operating Instructions, 08/2017, A5E37367739-AC
Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[unit]
(unit register)
Value range /
Setting options
Access
level
3462
Float / 4
Delta time path
2
Delta time
-
-
Read
only
3464
Float / 4
Travel time up
path 2
Travel time of up-
stream signal
-
-
Read
only
3466
Float / 4
Travel time
down path 2
Travel time of down-
stream signal
-
-
Read
only
3468
Float / 4
Correlation
factor path 2
Correlation factor
-
-
Read
only
3474
Unsigned / 2 Accepted burst
percentage
path 2
% of bursts accepted
(path 2).
Based on various di-
agnostic input (i.e.
correlation strength,
gain level, SNR, etc.)
the meter may reject
specific up/down re-
ceived sets or bursts.
The percentage of
accepted bursts is one
measure of the appli-
cation’s health.
-
-
Read
only
3475
Float / 4
Actual sensor
frequency path
2
Sensor frequency
-
-
Read
only
3479
Float / 4
Upstream peak
amplitude path
2
Upstream signal peak
amplitude
-
-
Read
only
3477
Float / 4
Downstream
peak amplitude
path 2
Downstream signal
peak amplitude
-
-
Read
only
3481
Float / 4
Fluid refraction
angle path 2
Calculated fluid refrac-
tion angle on path 2
(clamp-on only).
-
-
Read
only
Table A- 98 Path 3 diagnostics
Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[unit]
(unit register)
Value range /
Setting options
Access
level
3500
Float / 4
RxGain up path
3
Rx gain of upstream
signal
-
-
Read
only
3502
Float / 4
RxGain down
path 3
Rx gain of downstream
signal
-
-
Read
only
3504
Float / 4
SNR upstream
path 3
Signal to noise ration
of upstream signal
-
-
Read
only
3506
Float / 4
SNR down-
stream path 3
Signal to noise ration
of downstream signal
-
-
Read
only