Technical data
SITRANS F M TRANSMAG 2
74
Operating Instructions, 11/2009, A5E00102775-07
Significance
≦ 5000 pulses/s
Pulse width
≧ 0.1 ms
Frequency
≦ 10.000 Hz
Limits
For flow and quantity, flow direction, alarm
Digital output 2 (relay)
only 7ME5034-0....
Relay
NC or NO function
Rating
Rating max. 5 W, UC 50 V, 200 mA
Output configuration
limits for flow and quantity, flow direction, alarm
Digital input
Only as alternative to digital output 2 (only 7ME5034-2....)
Input function configurable high or low
active
Set measured value or counter to zero
Signal voltage
max. 30 V, Re = 3 kΩ
High level
DC +11 to 30 V
Low level
DC -30 to +5 V
PROFIBUS-PA
For PROFIBUS devices (7ME5034-1....)
Communication
Layer 1 and 2 according to PROFIBUS-PA
Transmission
According to IEC 1158-2
Protocol layer
Layer 7 according to PROFIBUS-PA and DP V1 (EN 50
170)
Device class
B
Device profile
3.0; max. 4 simultaneous C2 connections
Bus voltage
Permissible 9 to 32 V
Current consumption from bus
10 mA, limited to ≦ 15 mA in the event of an error by
electrical current limitation
Measuring accuracy under reference conditions
Table 10- 3 Measuring accuracy
Measuring tolerance of pulse output
At v > 0.25 m/s (0.82 ft/s)
≦ 0.5 % of the measured value, ± 0.0012 m/s (0.0039 ft/s)
At v < 0.25 m/s (0.82 ft/s)
≦ 0.0025 m/s (0.0082 ft/s)
Measuring tolerance of analog output 4
to 20 mA
Same as pulse output; plus ± 0.1 % conversion error ± 20
μA
Repeatability
0.2 % of the measured value
Reference conditions
Table 10- 4 Reference conditions
Medium process temperature
+25 °C ± 5 °C (77 °F ± 9 °F)
Ambient temperature
+25 °C ± 5 °C (77 °F ± 9 °F)
Warm-up time min.
30 min
Содержание SITRANS F M TRANSMAG 2
Страница 1: ...Electromagnetic Flowmeters SITRANS F M TRANSMAG 2 Operating Instructions 11 2009 SITRANS F ...
Страница 2: ......
Страница 10: ...Safety notes 2 2 Laws and directives SITRANS F M TRANSMAG 2 8 Operating Instructions 11 2009 A5E00102775 07 ...
Страница 14: ...Description 3 4 BUS Communication SITRANS F M TRANSMAG 2 12 Operating Instructions 11 2009 A5E00102775 07 ...
Страница 40: ...Commissioning 6 4 Operating examples SITRANS F M TRANSMAG 2 38 Operating Instructions 11 2009 A5E00102775 07 ...
Страница 92: ...Parameters SITRANS F M TRANSMAG 2 90 Operating Instructions 11 2009 A5E00102775 07 ...
Страница 108: ...Profibus Communication B 9 Literature list SITRANS F M TRANSMAG 2 106 Operating Instructions 11 2009 A5E00102775 07 ...
Страница 110: ...Appendix C 2 Accessories and spare parts SITRANS F M TRANSMAG 2 108 Operating Instructions 11 2009 A5E00102775 07 ...