Connection
4.8 Cables and connections
SINAMICS G110D
Operating Instructions, 07/2016, FW V3.63, A5E36768472B AB
51
NOTICE
Damage of the converter by disconnecting the motor during operation
The disconnection of the motor cable by a switch or contactor during operation may
damage the converter.
•
Disconnect converter and motor during operation only if it is necessary in terms of
personal security or machine protection.
Table 4- 16 Mains supply and motor output specifications
Mains supply
Motor output
Pin
Function
Pin
Function
1
L1
1
U
2
L2
2
Not connected
3
L3
3
W
4
-
4
EM Brake (-)
11
-
5
Temperature sensor (+)
12
-
6
EM Brake (+)
PE
Protective Earth
7
V
8
Temperature sensor (-)
PE
Protective Earth
Type HAN Q4/2 (Male)
Type HAN Q8 (Female)
Spec. 3AC 380V...500V
± 10%
Spec. -
Table 4- 17 Digital input specifications
Digital input (2 sockets, 4 DIs)
Pin
Function
1
+24 V (25mA max.)
2
DI1 or DI3
3
U0V
4
DI0 or DI2
5
Functional Earth
Shield Functional Earth
Type
M12 - 5 pole (Female)
Spec
PNP, SIMATIC-compatible, low < 5 V, high > 10 V, max. input voltage 30V