Functions
6.11 Operation in fieldbus systems
SINAMICS G110D
Operating Instructions, 07/2016, FW V3.63, A5E36768472B AB
173
Programmable process images
It is possible, using BICO, to change the functionality of both input and output process
images, with the exception of the CTT2 serial channel present in Slave 1. This serial channel
is required to be present in order that Slave 1 appears correctly on the AS-i network. The
default settings for both single slave and dual slave modes are given in the tables below.
Table 6- 58 Default input process image (slave to master) - Dual slave mode
Bit
Usage
Description
Slave 2
DI0
Ready
0: Inverter is not responsive to AS-i master
1: Inverter is ready to respond to commands from the AS-i master
DI1
Motor active
0: Inverter motor outputs are high impedance
1: Inverter motor outputs are active
DI2
Digital input 1
0: Input 1 is inactive
1: Input 1 is active
DI3
Digital input 2
0: Input 2 is inactive
1: Input 2 is active
Slave 1
DI0
Digital input 3
0: Input 3 is inactive
1: Input 3 is active
DI1
Digital input 4
0: Input 4 is inactive
1: Input 4 is active
DI2
Serial clock in
Clock signal for CTT2 data transfer to AS-i master
DI3
Serial data in
Data signal for CTT2 data transfer to AS-i master