Device Data
3-47
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
3.3
Diagnosis using the LEDs
The LEDs are explained in the order in which they are positioned on the C230-2.
Table 3-13
Diagnostic LEDs on the C230-2
Display
Function
Explanations
SF (red)
LED – ON
LED – flashes
(0.5 Hz)
LED – OFF
System fault
This LED indicates a fault on the C230-2.
An interrupt which can be acknowledged is present (alarm,
message, note).
(see Description of Functions SIMOTION Technology Func-
tions, Alarm Description.)
No license exists for technology/optional objects under license.
Technology/optional objects under license are, for example:
S
Position (position axis)
S
Cam (following axes with connected cam)
S
Gear (following axes with gearing)
S
Ethernet (Ethernet interface)
S
TControl (Temperature Control)
C230-2 is operating correctly.
5 VDC (green)
LED – ON
LED – OFF
Power supply for
the electronics
This LED indicates that the power supply is ready for operation.
The power supply of the C230-2 is functioning correctly.
If this is not illuminated, possible faults are:
S
No connected or switched-on network
S
No specified load power supply connected
S
Module not connected correctly
S
Module defective
RUN (green)
LED – ON
LED – flashes
(2 Hz)
C230-2 in RUN
This LED indicates that the user program is running.
The time from when the “RUN” operating mode is selected until
this operating mode has been attained is indicated by the LED
flashing.
STOPU (yellow)
LED – ON
LED – flashes
(2 Hz)
LED – “flickers”
C230-2 in STOP
User Program
This LED indicates that the technology packages are active. No
user program is being executed.
The time from when the “STOPU” operating mode is selected
until this operating mode has been attained is indicated by the
LED flashing.
Formatting the Micro Memory Card
Содержание SIMOTION C230-2
Страница 10: ...Table of Contents Contents 10 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 141: ...B 141 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition EC Declaration of Conformity B ...
Страница 144: ...EC Declaration of Conformity B 144 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...