Device Data
3-25
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
3.1.2
Memory module slot
7-pin connector to plug in a Micro Memory Card (MMC)
Micro Memory Card
The following Micro Memory Card is available:
Order no.: 6AU1 700-0AA01-0AA0
The Micro Memory Card can be used:
S
To save the SIMOTION Kernel (base system) in order to carry out an update
(see Section 9.1)
The SIMOTION Kernel should always be stored on the Micro Memory Card.
S
To save the technology packages and user data (programs, configuration data,
parameterization)
3.1.3
Ethernet interface
Interface for connecting a Fast Industrial Ethernet.
Fast Industrial Ethernet is a communication network with a transmission rate of
10/100 Mbit/s.
The C230-2 offers the following functions via the Ethernet interface:
S
Communications with STEP 7 and SIMOTION SCOUT
The “SIMATIC NET SOFTNET-PG (Protocol TPC/IP RFC 1006)” software must
be installed on the PG/PC for this function.
S
Communications between SIMOTION and SIMATIC NET OPC
The “SIMATIC NET SOFTNET-S7 (S7-OPC-Server)” software must be installed
on the PG/PC for this function.
Note:
SOFTNET-S7 is a superset of SOFTNET-PG, i.e. SOFTNET-S7 also contains
this Protocol TPC/IP RFC 1006.
For further information about the software packages, see Motion Control System
SIMOTION, PM 10 catalog, see List of References for the order number.
Connectable devices
A PG/PC can be connected to the Ethernet interface via a Fast Ethernet network.
The PG must be equipped with an Ethernet card and the corresponding software
must be available.
Содержание SIMOTION C230-2
Страница 10: ...Table of Contents Contents 10 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 141: ...B 141 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition EC Declaration of Conformity B ...
Страница 144: ...EC Declaration of Conformity B 144 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...