Device Data
3-21
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Interfaces
The interfaces and their functions are described in Table 3-1.
Table 3-1
Interfaces
Interfaces
Description
Bus connector
A rear-mounted connector for connecting the C230-2 with
other S7-modules over the P-bus
Drive interface
50-pin Sub-D connector X2 for the analog connection of
drives (max. 4 axes)
See Subsection 3.1.6
Measuring system interface
15-pin Sub-D sockets X3 to X6 for connection of encoders
(max. 4)
See Subsection 3.1.7
I/O interface
40-pin front connectors X1 for connecting the fast digital
inputs/outputs including measuring inputs, BEROs, and for
wiring the READY relay
See Subsection 3.1.8
Power supply connection
4-pin screw-type terminal connection X10 for connecting
the 24 V load power supply
See Subsection 6.2.1
Memory module slot
7-pin connector for Micro Memory Card
See Subsection 3.1.2
PROFIBUS DP1 interface
9-pin Sub-D socket X8 for connection to the PROFIBUS
DP. This interface can be used for isochronous operation.
See Subsection 3.1.4
PROFIBUS DP2/MPI
interface
9-pole X9 Sub-D socket for connection to PROFIBUS DP
(default setting) or an MPI bus.
This interface can be used for isochronous operation.
See Subsection 3.1.4
Ethernet
interface
8-pin RJ45 socket X7 for connection to a Fast Industrial
Ethernet
Содержание SIMOTION C230-2
Страница 10: ...Table of Contents Contents 10 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 141: ...B 141 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition EC Declaration of Conformity B ...
Страница 144: ...EC Declaration of Conformity B 144 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...