Device Data
3-36
E
Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Connector pin assignment
Designation:
X3, X4, X5, X6 ENCODER 1...4
X3
Axis 1
X4
Axis 2
X5
Axis 3
X6
Axis 4
Type:
15-pin Sub-D socket connector
Table 3-7
Assignment of connectors X3 to X6
Encoder
Encoder
Pin
Incremental
Absolute
Type
Pin
Incremental
Absolute
Type
1
Unassigned
9
MEXT
VO
2
CLS
O
10
Z
I
3
CLS_N
O
11
Z_N
I
4
P5EXT
VO
12
B_N
I
5
P24EXT
VO
13
B
I
6
P5EXT
VO
14
A_N
DATA_N
I
7
MEXT
VO
15
A
DATA
I
8
Unassigned
Signal names
A, A_N
Track A non-inverted and inverted (incremental encoder)
B, B_N
Track B non-inverted and inverted (incremental encoder)
Z, Z_N
Zero mark non-inverted and inverted (incremental encoder)
CLS, CLS_N
SSI cycle clock shift pulse non-inverted and inverted (absolute
encoder)
DATA, DATA_N
SSI data non-inverted and inverted (absolute encoder)
P5EXT
+5 V supply
P24EXT
+24 V supply
MEXT
Ground supply
Signal type
VO
Voltage output (supply)
O
Output (5 V signal)
I
Input (5 V signal)
Содержание SIMOTION C230-2
Страница 10: ...Table of Contents Contents 10 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 16: ...Product Overview 1 16 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 70: ...Installation 4 70 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 124: ...Commissioning 8 124 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 130: ...Maintenance 9 130 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...
Страница 141: ...B 141 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition EC Declaration of Conformity B ...
Страница 144: ...EC Declaration of Conformity B 144 E Siemens AG 2003 All rights reserved SIMOTION C230 2 04 2003 Edition ...