7
7.1 Phasor Measurement Unit (PMU)
63
Digital Fault Recorder, SIMEAS R-PMU, Manual
E50417-H1076-C360-A5, Release 10.2012
Measures to reduce the data rate.
−
Decreasing the reporting rate
−
Transfer of 16 bit integer data instead of 32 bit floating point data
−
Transfer of positive sequence system data instead of phasors
−
Deactivating one DAU for PMU measurements
Table 7-8
Serial or modem transmission:
Data transfer rate depending on the configuration and reporting rate in kbit/s,
data format 16 bit integer
Configuration
Type
Reporting rate (Hz)
10
12
15
20
25
30
50
60
1 AC DAU
Positive-sequence system
3
4
5
6
8
9
15
18
1 AC DAU
Phasors
5
6
7
10
12
15
25
30
2 AC DAUs
Positive-sequence system
4
5
6
9
11
13
21
26
2 AC DAUs
Phasors
8
10
12
16
20
24
40
48
4 AC DAUs
Positive-sequence system
7
8
10
14
17
20
34
41
4 AC DAUs
Phasors
14
17
21
29
36
43
71
86
1 DDAU
Process values
4
4
6
7
9
11
18
22
2 DDAUs
Process values
6
7
8
11
14
17
28
33
1 BDAU
Binary values
3
3
4
5
6
8
13
15
2 AC DAUs
2 DDAUs
Positive-sequence system/
process values
9
11
14
19
23
28
46
56
2 AC-DAUs
1 DDAU
1 BDAU
Phasors /
process values /
binary values
11
13
16
21
27
32
54
64
Note
The 32 bit floating point data format is not supported for the PMU data communication via
RS232.
Содержание SIMEAS R-PMU
Страница 22: ...3 22 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 40: ...5 5 4 Monophase Connection 40 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 114: ...9 114 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 130: ...11 130 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 210: ...14 14 4 Commissioning 210 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 260: ...17 260 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 274: ...18 18 4 Time Synchronization 274 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 290: ...5 Special Note Open Source Software 290 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 292: ...Literature 292 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...
Страница 296: ...Index 296 Digital Fault Recorder SIMEAS R PMU Manual E50417 H1076 C360 A5 Release 10 2012 ...