Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
228
Configuration Manual, 03/2018, C79000-G8976-C386-06
</reply>
</frame>
// opt → Optional: Line can be omitted. In the reply, the parameter is transferred depending
on the configuration settings (Settings - Communication).
The error codes for negative replies
("resultCode" ≠ 0) are described in the section "
XML replies (Page 263)".
Parameter
Parameter
Type
Values
Description
value_id
Decimal value
0...9
0...4294967295
Unique command identifier
value_
sourceName
Text
--
Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 54)").
In the standard configuration, there is
only one read point with the name
"Readpoint_1".
value_duration
Decimal value
0...9
0...65535
Optional
Duration for which the selected read
point will read transponders.
If the value "0" is set or the parameter
is empty, only one read cycle is exe-
cuted.
value_unit
Fixed values
Time
Count
Optional
Specifies the unit for the duration.
•
Time = time in milliseconds
•
Count = number of inventories
If no value is set, the duration is speci-
fied in milliseconds.
value_tagID
Hexadecimal
value
0...9, A...F
--
EPC-ID in "RAW Hex Data Format".
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
value_utcTime
Time
--
Optional
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
value_
antennaName
Fixed values
Antenna01
Antenna02
Antenna03
Antenna04
Optional
Name of the antenna