Programming via Rockwell controller
9.5 Programming add-on instructions
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
167
Table 9- 8
Explanation of the "Config_Upload" block
Parameter
Data type
Description
IDENT_DATA
SINT[10]
Data buffer for configuration data.
The real length of the data depends on the com-
plexity of the configuration and the firmware
version of the reader. With a standard configura-
tion of the RF680R/RF685R reader, we recom-
mend a memory size of 4 KB. If you use
advanced reader configurations (filtering) or
want to change the configuration in the future
without needing to adapt the memory size of
"DATA", we recommend a memory size of 8-16
KB.
Note.
When necessary a byte/array of any size can be
transferred to this parameter. Note that the array
must be ≥ 10 bytes long (e.g. "SINT[12400]").
Figure 9-8
"Config_Download" block
Table 9- 9
Explanation of the "Config_Download" block
Parameter
Data type
Description
IDENT_DATA
SINT[10]
Data buffer for configuration data.
The real length of the data depends on the com-
plexity of the configuration and the firmware
version of the reader. With a standard configura-
tion of the RF680R/RF685R reader, we recom-
mend a memory size of 4 KB. If you use
advanced reader configurations (filtering) or
want to change the configuration in the future
without needing to adapt the memory size of
"DATA", we recommend a memory size of 8-16
KB.
Note.
When necessary a byte/array of any size can be
transferred to this parameter. Note that the array
must be ≥ 10 bytes long (e.g. "SINT[12400]").