Programming via XML interface
10.3 XML commands
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
235
Parameter
Parameter
Type
Values
Description
value_id
Decimal value
0...9
0...4294967295
Unique command identifier
value_
sourceName
Text
--
Read point name
The name is specified using the WBM
(refer to the section "The "Settings -
Read points" menu item (Page 54)").
In the standard configuration, there is
only one read point with the name
"Readpoint_1".
value_tagID
Hexadecimal
value
0...9, A...F
--
Optional
EPC-ID in "RAW Hex Data Format".
This function applies to all transpond-
ers with this ID.
If this parameter is empty or not even
transferred, the function applies to all
transponders. Nevertheless only one
transponder is then permitted in the
antenna field.
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
value_newID
Hexadecimal
value
0...9, A...F
--
New EPC-ID in "RAW Hex Data For-
mat" to be written to the transponder.
Example of a 96-bit EPC-ID:
3005FB63AC1F3681EC880468
For additional information, refer to the
"EPC Global Specification".
value_idLength
Decimal value
0...9
16, 32, 48...496
Optional
Length of the new EPC-ID in bits.
If this parameter is set, the reader
checks the correct length of "val-
ue_newID". If the check fails, a nega-
tive reply is sent.
Without this parameter, the new EPC-
ID is only checked if the length is a
multiple of 16 bits.
value_password
Hexadecimal
value
0...9, A...F
00000000….
FFFFFFFF
Optional
Access password for the transponder
This parameter does not need to be
defined if there is no password protec-
tion activated for the transponder.
value_utcTime
Time
--
Optional
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.