Programming via XML interface
10.4 XML EventReports
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
269
Parameter
Type
Values
Description
rSSIMax
Decimal value
0...9
0...255
The highest RSSI value with which the
transponder was detected. This is a
value without a unit and without direct
reference to the power strength.
value_channel
Decimal value
0...9
1...50
Optional
Channel number on which the tran-
sponder was detected.
value_power
Decimal value
0...9
0, 5.00...33.00
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
value_polarization Fixed values
Circular
Vertical
Horizontal
Unknown
Polarization of the antenna.
With external antennas always un-
known.
value_inventoried Decimal value
0...9
0...65535
Optional
Indicates how often the transponder
was identified via the air interface be-
fore it changed to the "Observed" sta-
tus.
Value_
filterDataAvailable
Fixed values
True
False
Optional
Indicates whether or not a filter criteri-
on was received.
•
True:
No problem. All the data was read
or there was no filter set.
•
False:
Data could not be read.
value_fieldName
Text
--
Name of tag field
Is specified in the WBM (refer to the
section "The "Settings - Tag fields"
value_bank
--
0...3
Memory bank of the tag field
•
0: Reserved
•
1: EPC
•
2: TID
•
3: USER MEMORY
value_
startAddress
Decimal value
0...9
0...65535
Start address of the first byte in the
memory bank where reading will start.