![Siemens SIMATIC RF650R Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/siemens/simatic-rf650r/simatic-rf650r_configuration-manual_382148096.webp)
Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF650R/RF680R/RF685R
96
Configuration Manual, 03/2018, C79000-G8976-C386-06
With the "Update", "Save as" and "Reset" buttons, you can control the entries:
●
Update
The log is read in again from the reader and the list updated. The displayed log entries
contain 200 KB of data.
●
Total history
The complete stored log of the reader is read in. The displayed log entries contain 10 MB
of data.
●
Save as
The log read out from the reader is stored as a *.log file on the PC.
●
Reset
The log is deleted on the reader.
With a large number of log entries in the history, it may take several minutes before these
are displayed.
Service support by SIEMENS specialist personnel
By changing the address line in the browser, and additional menu item for service purposes
can be called. To do this, change the value of the page to 11
(http://192.168.0.55/Default.mwsl#page=11). Apart from displaying internal instructions, via
this menu a "Service Log File" can also be stored by the reader on the PC.
This file records internal sequences of the reader and is required for service support by
SIEMENS specialists. Reading out the data can under certain circumstances impair the
performance of the reader and it should therefore only be read out if requested by SIEMENS
service.