Installing system components
3.6 Connecting the connection box
TP1000F Mobile RO
60
Operating Instructions, 08/2017, A5E39831415-AA
Connection boxes standard and advanced
1.
Strip the insulation on the Ethernet cable as shown in the figure below.
2.
Open fast connector 1.
①
Fast connector 1
②
Fast connector 2
③
Screw gland
3.
Push the Ethernet cable through the screw gland and connect the wires as detailed in the
interface description in "Internal interface X1 P1 (Page 174)".
4.
Close the fast connector.
Closing the fast connector establishes the contact to the wires in the Ethernet cable.
5.
Tighten the screw cap on the screw gland.
Degree of protection IP65 is only ensured once the screw cap has been tightened.
6.
Once all the required work in the connection box has been completed, close it.