Parameterizing the Mobile Panel
5.13 Functions for service and commissioning
TP1000F Mobile RO
128
Operating Instructions, 08/2017, A5E39831415-AA
If the "Automatic Backup" function is currently disabled ("Enabled: No"), the "Enable &
Reboot" button is displayed.
3.
Press the "Disable & Reboot" or "Enable &Reboot" button to disable or enable the
automatic backup.
The "System card" dialog is displayed.
4.
Press the "Yes" button.
Note
There is no message whether a storage medium is inserted / not inserted.
An automatic restart is carried out.
Applications
We differentiate between the following different cases, depending on whether the system
memory card was previously used for automatic backup: