Output ranges for current: 0 to 20 mA; 4 to 20 mA
Table 13-28 SIMATIC S7 format: Output ranges 0 to 20 mA; 4 to 20 mA
Output range
0 to 20 mA
Output range
4 to 20 mA
Units
Range
decimal
hexadecimal
0
0
> 32511
> 7EFF
H
Overflow
23,5178
22,8100
32511
7EFF
H
Overrange
:
:
:
:
20,0007
20,0005
27649
6C01
H
20,0000
20,0000
27648
6C00
H
:
:
:
:
Nominal range
0
4,0000
0
0
H
0
3,9995
-1
FFFF
H
Underrange
:
:
:
:
0
0
-6912
E500
H
0
0
< -6913
< E4FF
H
Underflow
13.9
Fundamentals of analog value processing
13.9.1
Wiring thermocouples
Introduction
This section contains additional information on connecting thermocouples.
Analog electronic modules
13.9 Fundamentals of analog value processing
ET 200iSP