B-4
C7-621 / C7-621 AS-i Control Systems
C79000-G7076-C621-01
B.3
General Protective Measures Against Electrostatic Discharge
Damage
Keep plastics away from sensitive devices. Most plastic materials have a
tendency to build up electrostatic charges easily.
Make sure that the personnel, working surfaces and packaging are
sufficiently grounded when handling electrostatically sensitive devices.
If possible, avoid any contact with electrostatic sensitive devices. Hold
modules without touching the pins of components or printed conductors. In
this way, the discharged energy cannot affect the sensitive devices.
Note the following measures that have to be taken for modules that are not
protected against accidental contact:
S
Touch electrostatic sensitive devices only
–
if you wear a wristband complying with ESD specifications or
–
if you use special ESD footwear or ground straps when walking on an
ESD floor.
S
Persons working on electronic devices should first discharge their bodies
by touching grounded metallic parts (e.g. bare metal parts of switchgear
cabinets, water pipes, etc.).
S
Protect the modules against contact with chargeable and highly insulating
materials, such as plastic foils, insulating table tops or clothes made of
artificial fibers.
S
Place electrostatic sensitive devices only on conductive surfaces:
–
Tables with ESD surface
–
Conductive ESD foam plastic (ESD foam plastic is mostly colored
black)
–
ESD bags
S
Avoid direct contact of electrostatic sensitive devices with visual display
units, monitors or TV sets (minimum distance to screen > 10 cm).
Keep Plastics
away
Provide Sufficient
Grounding
Avoid any Contact
Additional
Precautions for
Modules without
Housings
Guidelines for Handling Electrostatically Sensitive Devices (ESD)
Содержание simatic c7-621
Страница 44: ...2 26 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Installing and Preparing the C7 ...
Страница 64: ...3 20 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Configuring an MPI Network ...
Страница 74: ...5 4 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Attaching a C7 621 AS i ...
Страница 82: ...6 8 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 C7 621 Digital I Os ...
Страница 100: ...7 18 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 C7 621 Analog I Os ...
Страница 101: ...8 1 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Maintenance 8 ...
Страница 110: ...A 8 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 General Technical Specifications ...
Страница 123: ...Glossary 1 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Glossary ...
Страница 136: ...Index 4 C7 621 C7 621 AS i Control Systems C79000 G7076 C621 01 Index ...