12
SICAM Q80 7KG8080
Power Quality Recorder SICAM Q80 7KG8080, System manual
E50417-H1076-C420-A2, Release 12.01.2015
3.2
Computation procedures
Concept of SICAM Q80 7KG8080
The computations are performed in accordance with the standard IEC 61000-4-30 Ed.2 class A compliant for the
following:
Frequency
Magnitude of Supply Voltage
Flicker
Voltage Dips, Swells, Interruptions
Unbalance
Harmonics
Mains Signaling
Time clock uncertainty
Flagging
Note
SICAM Q80 7KG8080
is designed to be used in either 50 Hz or 60 Hz grids.
The sample values presented pertain to a low voltage power network of 50 Hz and 230 V; in
case of any deviations, the nominal voltage or network frequency is noted.