RUGGEDCOM MX5000RE
Installation Guide
Chapter 2
Installing the Device
Connecting Power to the Enclosure
27
• Use minimum #16 gage copper wiring when connecting terminal blocks.
• For 125/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
• For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker must be installed.
• It is recommended to provide a separate circuit breaker for each power module module.
• Equipment must be installed according to applicable local wiring codes and standards.
CONTENTS
•
Section 2.15.1, “Connecting Power to the Enclosure”
Section 2.15.1
Connecting Power to the Enclosure
To complete the power circuit, connect an external power supply to the PS1 and/or PS2 patch panels using male
Amphenol MIL-DTL 389999 size 13, code N connectors.
Figure 21: Power Supply Panel Connector
Pin
Description
A
PS LIve/+
B
Spare
C
PS Neutral/-
D
Spare