RUGGEDCOM MX5000RE
Installation Guide
Chapter 2
Installing the Device
Installing the Fan Tray Cables
15
2
1
3
Figure 9: Failsafe Alarm Relay Wiring
1.
Normally Open
2.
Common (Ground)
3.
Normally Closed
Pin
Function
NC
Normally Closed
Common
Ground
NO
Normally Open
The failsafe relay terminal is connected to the patch panel for the CM using the cable assembly provided. The
connector is an Amphenol MIL-DTL 38999 size 13, code
A
. The following is the pin-out for the connector:
Figure 10: Failsafe Relay Alarm Panel Connector
Pin
Description
A
COM (Common)
B
NO (Normally Open)
C
NC (Normally Closed)
D
Spare
Section 2.6
Installing the Fan Tray Cables
1. Apply Loctite® 222 to the threads of the fan tray cable connector threads.