RUGGEDCOM MX5000RE
Installation Guide
Chapter 2
Installing the Device
Installing the Patch Panels
23
Section 2.11
Installing the Patch Panels
To install a patch panel, do the following:
NOTE
The following procedure also applies for blank patch panels.
1. From the bottom of the enclosure, feed the patch panel cables through the appropriate opening. For more
information about which patch panels correspond to which openings, refer to
.
1
2
Figure 18: Patch Panel Installation
1.
#6-32×5/8" SS304 Truss Head Philips Drive Screw
2.
Patch Panel
2. Align the patch panel with the screw holes surrounding the patch panel opening.
3. Apply Loctite® 242 to each screw.
4. Secure the patch panel to the enclosure with eight (8) screws for large panels, or four (4) for small panels.
Hand-tighten the screws evenly in a cross pattern. There should be no visible gap between the patch panel