Service and maintenance
8.2 Checking and changing lubricants
BA 2010
Operating Instructions, 02/2018, A5E38093846A/RS-AC
71
For a +80 °C oil sump temperature, the following service life can be expected when
observing the properties specified by Siemens AG:
Table 8- 6
Service life of the oils
Type of oil
Service life
Mineral oil
10 000 operating hours or 2 years
Biodegradable oil
Physiologically safe oil according to USDA-H1/-H2
Synthetic oil
20 000 operating hours or 4 years
①
Mineral oil
②
Synthetic oil
T
Oil-bath long-term temperature [°C]
I
Oil change interval in operating hours [h]
Figure 8-6
Guide values for oil change intervals
Grease service life of roller bearing greases
Roller bearings and the clearance in front are filled with sufficient grease.
Under approved operating conditions and ambient temperatures, no regreasing is required.
We recommend that the grease filling of the bearings is also changed when the oil or shaft
sealing rings are replaced.