Commissioning
5.3 Vent filter
BA 2010
50
Operating Instructions, 02/2018, A5E38093846A/RS-AC
5.3
Vent filter
Vent filter without securing clip
In the case of gearboxes with housing ventilation, the necessary vent filter or pressure
breather valve without a securing clip is delivered separately. They must be replaced with
the appropriate vent plug before starting up the gearbox.
Observe the symbol in the type of construction diagrams, see Mounting positions (Page 87):
Ventilation
Procedure
1.
Unscrew the vent plug.
2.
Seal the gearbox with the vent filter or the pressure breather valve without securing clip.
You have now replaced the vent filter or pressure breather valve with the vent plug without
the securing clip.
Pressure breather valve with securing clip
The pressure breather valve with securing clip
①
is fitted to gearboxes which require
housing ventilation.
Figure 5-1
Pressure breather valve with securing clip
Remove the transport fixture by pulling the securing clip
①
in the direction of the arrow.
5.4
Gearbox with backstop (optional)
NOTICE
Running in the wrong direction of rotation can damage the geared motor
Check the direction of rotation before starting up.
Turn the input side or motor over manually.
Use the phase sequence to check the direction of motor rotation and swap the two external
conductors if necessary.
Содержание MOTOX BA 2010
Страница 1: ......
Страница 2: ......
Страница 8: ...Table of contents BA 2010 6 Operating Instructions 02 2018 A5E38093846A RS AC ...
Страница 54: ...Operation BA 2010 52 Operating Instructions 02 2018 A5E38093846A RS AC ...
Страница 82: ...Disposal BA 2010 80 Operating Instructions 02 2018 A5E38093846A RS AC ...
Страница 123: ......
Страница 124: ......