BA 5060 EN 04/2011
6
8
1
2
3
4
5
7
Fig. 22:
Gearunit features for oil change
1
Oil dipstick
5
Screw plug for residualoil drainage
2
Wetair filter / screw plug
6
Screw plug with sealing ring
3
Oildrain cock / oildrain plug
7
Oil filter
4
Screw plug for oil inlet
8
Lubricating point
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
•
Place a suitable container under the oildraining point of the gearunit housing.
•
If necessary connect a maintenance hose.
•
Unscrew the wetair filter on the top of the housing.
•
Unscrew the oildrain plug or open the oildrain cock and drain the oil into the collecting container.
There is a danger of scalding from the hot oil emerging from the housing.
Wear protective gloves.
Any oil spillage must be removed immediately with an oilbinding agent.
Check the condition of the sealing ring (the sealing ring is vulcanised onto the oildrain plug).
If necessary, use a new oildrain plug.
•
Clean the permanent magnet of the oildrain plug (if available) thoroughly.
•
Screw in the oildrain plug or reclose the oildrain cock.
•
Clean the oil filter in the oilcooling system as described in item 10.2.3.
•
Replace the wetair filter, if necessary (see item 10.2.4).
•
Screw in the wetair filter.
•
Fill fresh oil into the gear unit (see item 7.1.2).