BA 5060 EN 04/2011
In case of gear units fitted with forced lubrication or an oilcooling system, the oil circuit must
also be charged with oil. To do this, briefly start up the gear unit with the addon pump
(observing the description in section 8).
•
Screw in the oil dipstick or plug screw.
•
Check the oil level in the gearunit housing with the oil dipstick screwed in and/or by means of the
oilsight glass.
When the oil is cool, the oil level should be at the upper mark on the oil dipstick screwed in.
When the oil is warm it may slightly exceed this mark. It must in no case be allowed to fall below
the mark. If necessary, top up to the correct level. The greaselubricated output bearing is
protected by an oildam pipe from oil (see item 5.6.2).
Any oil spillage must be removed immediately with an oilbinding agent.
7.1.2.1 Oil quantities
The oil quantity is indicated on the rating plate fitted to the gear unit.
7.1.2.2 Greaselubricated rolling bearing
The gear unit is delivered ex works with the necessary grease charge for the lower outputshaft
bearing.
1
Lower output-shaft bearing
2
Lubricating point
1
2
Fig. 20:
Lubricating point for lower outputshaft bearing
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
For longer periods of storage (> 6 months) in a situation which is different from the mounting position,
a corresponding quantity of grease (see table 9) should be repacked using a grease gun prior to initial
operation. For the correct type of grease, refer to the table "T7300" (for a link, see the BA 7300 document
supplied separately).
Table 9:
Grease quantities for the lower outputshaft bearing for shutdown period > 6 months
Type
Grease quantity (standard value in kg) for gear-unit size
105
106
107
108
109
110
111
112
H2NV
0.200
0.300
0.300
0.400
0.500
0.700
0.700
0.900
If the gear unit has not been in use for more than 36 months or if the lower outputshaft bearing has been
inspected or renewed, the bearing space must be filled with the amount of rollingbearing grease specified
in table 10. For the correct type of grease, refer to the table "T7300" (for a link, see the BA 7300 document