Communication
6.2 Cyclic Communication
Control Units CU240S
Operating Instructions, 07/2008 - FW 3.2, A5E00766042B AD
129
Telegram structure and settings of P0922
Table 6-6
Standard telegrams from 1 to 999
Telegramm
Parameter
channel
Process data area (PZD)
PZD01
STW1
ZSW1
PZD 02
HSW
HIW
PZD
03
PZD
04
PZD
05
PZD
06
PZD
07
PZD
08
STW1
NSOLL_A
⇐ Receive telegram from PROFIBUS
Telegram 1
Speed control,
2 words
-
ZSW1
NIST_A
⇒ Send telegram to PROFIBUS
STW1
NSOLL_A
Telegram 20
Speed control,
VIK/NAMUR
-
ZSW1
NIST_A_
GLATT
IAIST
MIST
PIST
<1>
STW1
NSOLL_A
M_LIM STW2
Telegram 350
Speed control,
4 words
-
ZSW1
NIST_A_
GLATT
IAIST_ ZSW2
STW1
NSOLL_A
<3>
<3>
<3>
<3>
Telegram 352
Speed control, PCS7
-
ZSW1
NIST_A_
GLATT
IAIST
MIST
FAULT_
CODE
WARN_
CODE
X
STW1
NSOLL_A
Telegram 353 Speed
control,
PKW 4/4 and
PCD 2/2
X
ZSW1
NIST_A_
GLATT
X
STW1
NSOLL_A
<3>
<3>
<3>
<3>
Telegram 354 Speed
control,
PKW 4/4 and
PCD 6/6
X
ZSW1
NIST_A_
GLATT
IAIST
MIST
FAULT_
CODE
WARN_
CODE
STW1
<1>
Receive telegram length is max. 8 words. It can be freely selected via the
central PROFIBUS configuring, e. g. HW Config (universal modul in
GSD) <2>
Telegram 999
Free interconnection
via BICO
-
ZSW1
<1>
Send telegram length is max. 8 words. It can be freely selected via the
central PROFIBUS configuring, e. g. HW Config (universal modul in
GSD) <2>
<1> In order to comply with the PROFIdrive profile, PZD1 must be used as STW1 or ZSW1
<2> Structure like a standard telegram
<3> Placeholder for PCS7 process data
STW1/2 (r2090/r2091)
ZSW1/2 (r0052/r0053)
NSOLL_A *) (P1070)
NIST_A *) (r0021)
IA_IST (r0027)
MIST (r0031)
PIST (r0032)
M_LIM (P1522)
FAULT_CODE (r2131)
WARN_CODE (r2132)
Control word 1/2
Status word 1/2
Speed setpoint A (16 bit)
Speed actual value A (16 bit)
Output current
Torque actual value
Active Power
Torque limit
Fault code
Warn code
*) NSOLL_A, NIST_A are FSOLL and FIST for SINAMICS G120