![SICK SIG200 Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/sick/sig200/sig200_operating-instruction_1264337073.webp)
7.4.6.3
gateway
GET/gateway/identification
Readout of identification information.
Sample response:
{
"macAddress": "00:06:77:00:00:00",
"serialNumber": "12345678",
"productId": "1234567",
"vendorName": "SICK AG",
"productName": "SIG200-0A0G12200",
"hardwareRevision": "V1.0.0",
"firmwareRevision": "1.3.0.0B"
}
GET/gateway/capabilities
Information about device function.
JSON parameters Type
Description
ioddSup-
ported
Boolean
Describes the general support for IODD files. This
includes uploading IODDs and allows parameter access
via variable names. In addition, it offers the advantage
that values are output directly in the appropriate format.
mqttSup-
ported
Boolean
Describes the general support of MQTT.
Sample response:
{
"ioddSupported": true,
"mqttSupported": false
}
GET/gateway/configuration
POST/gateway/configuration
Reading and writing the device configuration or Ethernet settings.
JSON parameters Type
Description
ipConfigura-
tion
Enum
[“DHCP”/ “MAN‐
UAL”]
Describes the general support for IODD files. This
includes uploading IODDs and allows parameter access
via variable names. In addition, it offers the advantage
that values are output directly in the appropriate format.
Sample request:
SIG200 CONFIGURATION
7
8017853.1D0S/2021-11-04 | SICK
O P E R A T I N G I N S T R U C T I O N | Sensor Integration Gateway - SIG200
73
Subject to change without notice