Chapter
8
Operating Instructions
CLX490 Compact OMNI Scanner
8-6
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Troubleshooting
6. "warning: additional
unknown parameter(s)
external parameters
loaded"
(Error type: 101, 114)
Start option: S
TART
WITH
E
XTERNAL
P
ARAMETERS
.
The CLX has successfully
loaded the external parameter
set with tolerated errors
1)
to its
RAM.
Transfer ok but different parame-
ter versions in the external
memory and the CLX.
Upload the parameter set to CLV-
Setup and check the values
1)
.
1) The software of the parameter set in the CLX is older than that of the parameter set in the external memory: print out the parameter set using CLV-Setup. If necessary,
display the ID of the unknown/errored command group(s) using the <STX> 8?ERR <ETX> command in the Terminal Emulator window of CLV-Setup. Decode the ID using
the reference manual entitled Command Language of the CLV Bar Code Scanners and check the relevant parameter values in the tabs.
The software of the parameter set in the CLX is newer than that of the parameter set in the external memory: all of the new parameters in the CLX are set to the default
values. If these parameters are necessary, edit the values in the relevant tabs in CLV-Setup and download them to the CLX and the external memory.
Message
Meaning
Possible cause
Remedy