Chapter
6
Operating Instructions
CLX490 Compact OMNI Scanner
6-26
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Operation
•
incorrect parameter settings
•
errors during data transmission to the host
Chapter 8.3 Error messages, Page 8-2
lists the messages with the associated corrective
measures.
Note
To call up the most recent error to occur in the CLX, enter command "2?SF" in the command
line of the terminal emulator.
6.7
Switching off the CLX
1.
If the parameter set was modified in CLV-Setup or was only stored temporarily in CLX
via a download ("Temproray" option or via context menu (right mouse button)), the
parameter set must be stored permanently in the CLX by choosing the P
ERMANENT
storage option.
2.
Save the parameter set as a configuration file "*.scl" in CLV-Setup.
3.
Switch off the power supply of the AMV/S60 or unplug both of the CLX’s connecting ca-
bles from the connection module.
The last parameter set stored permanently in the CLX remains valid.
Archiving the parameter set:
We recommend that you print out the configuration file in order to archive the parameter set.
1.
Click
in the toolbar.
The P
RINT
FILE
dialog box is then displayed.
2.
Enter a comment in the input field in order to assign the printout to the CLX.
Confirm your entry with OK.
The P
RINT
dialog box for configuring the printer is then displayed.
3.
Make the necessary entries in the dialog box and confirm these.
CLV-Setup prints out the current configuration file in the form of a table.